Introduction: YT106 is a compact two-Form-C signal relay and general purpose power relay with 3–24 VDC coil options, sized for control panel and automation circuit evaluations where low-current switching and two changeover contacts matter.
The relay measures 20.2 × 10 × 11.5 mm and weighs about 5.0 g. In a control panel candidate list, the practical review centers on panel duty, coil supply, contact load, and available space; the product data supports that review, while the final circuit check belongs with the panel design and supplier drawing review.
Inside a control panel, a signal relay may pass interlock status to a PLC input card, switch a small indicator lamp, isolate a measurement channel, or carry a go/no-go signal between circuit blocks. YT106 is intended for this kind of low-current switching, and the panel duty should be defined before the relay is compared with alternatives. Its resistive load ratings are 1 A at 125 VAC and 2 A at 30 VDC. Maximum switching current is 2 A, maximum switching voltage is 125 VAC or 30 VDC, and maximum switching power is 125 VA or 60 W. These are separate limits; do not combine them into a new load rating. The application notes cover industrial automation, control panels, measurement and test, compact electronics, robotics, and instrumentation circuits. A practical evaluation can start with a 24 VDC signal path and a low-current interlock or status circuit. In that setting, the useful question is whether two independent changeover contacts simplify the drawing. One contact group can report an interlock state while the second drives a panel lamp or a second input. Silver alloy contacts and a contact resistance of 100 mΩ maximum suit the low-current end of the range. Motors, high-inrush loads, and capacitive loads sit outside the resistive reference and need their own engineering review.
Coil and contact decisions belong together. A coil that the control board cannot drive reliably makes a good contact unusable, and a contact oversized for the signal adds cost and space without benefit. YT106 offers 3, 5, 6, 9, 12, and 24 VDC coils across three power groups of about 0.15 W, 0.20 W, and 0.36 W. Drive current changes with the selected coil, so match the driver to the exact option rather than to the model family as a whole.
The contact arrangement is marked 2C, Form C, 2 Group, which means two independent changeover groups. Each group has a common terminal, a normally open contact, and a normally closed contact. In a panel drawing, the normally closed side can carry a path that stays live while the coil is de-energized, and the normally open side closes a status line when the coil picks up. Keeping two groups in one compact body lets one relay handle interlock feedback and an indicator circuit, which can make tracing and troubleshooting easier than using two separate relays.
On a 24 VDC rail, the published currents are about 6.3 mA for the 0.15 W group, 8.3 mA for the 0.20 W group, and 15 mA for the 0.36 W group. The published coil data for the 0.36 W group contains an inconsistency that is worth checking before that version enters a design. The 150 mW option is one coil choice, not every YT106 build, and the ordering code for the 0.15 W version is not spelled out in the published data. Request the exact code with the required voltage. Operate time is 6 ms maximum at rated voltage, and release time is 4 ms maximum without a diode. In relay driver circuits, a flyback diode changes release behavior, so interlock timing should account for the actual driver arrangement.
Space on a control panel is rarely generous. The 20.2 × 10 × 11.5 mm body and roughly 5.0 g unit weight provide a starting point for layout, but the drawing should define orientation, terminal positions, and keep-out areas. YT106 documentation includes an outline drawing, a bottom-view PCB layout, and a bottom-view wiring diagram, all in millimetres, with a ±0.1 mm layout tolerance noted. Ask for the current versions and terminal definitions before the panel or carrier-board drawing is frozen. Wiring needs the same attention as dimensions. Each changeover group requires its common, normally open, and normally closed connections. Allow room for wire entry and for a test probe on every terminal, and keep coil wiring away from sensitive signal runs where the layout allows. Ambient temperature is rated from -40°C to +85°C, non-condensing; local heat sources still belong in the thermal review. The S ordering suffix is listed as Flux proofed. Flux proofed is not an IP rating, so wash-down or humid areas still need enclosure protection. Coil switching produces transients, and EMC is a system-level consideration for the assembled panel. General relay driver and flyback context, along with system-level EMC guidance, can inform the panel design review, while YT106 technical data provides the model facts.
YT106 is worth adding to a control panel candidate list when the panel needs low-current signal switching, two independent changeover contacts, and a coil that matches a 3–24 VDC rail. The strongest panel-related facts are the compact 20.2 × 10 × 11.5 mm body, two Form C groups, 6 ms maximum operate time at rated voltage, and the -40°C to +85°C non-condensing ambient range. Provide the planned coil voltage, switched load, channel count, and available space; ask for the full ordering code, current drawings, terminal definitions, and model-specific certificates. Price, MOQ, stock, and lead time require separate confirmation. For a control panel project, a signal relay manufacturer such as YongNeng Relay Manufacturer can review those details and confirm the exact version. If you compare YT106 with a quote from another miniature power relay supplier, tie both quotes to the same complete ordering code.
A: In low-current parts of the panel: interlock status feedback to a PLC input, indicator and lamp circuits, go/no-go signals between circuit blocks, and measurement or instrumentation channels. The resistive ratings of 1 A at 125 VAC and 2 A at 30 VDC are the working reference, with maximum switching limits of 2 A, 125 VAC or 30 VDC, and 125 VA or 60 W listed separately. Two changeover contacts let one relay serve two signal paths. Motor, high-inrush, and capacitive loads require separate review.
A: The 2C, Form C, 2 Group marking means two independent changeover groups, each with a common, normally open, and normally closed terminal. One group can close a status line to a PLC input when the coil is energized, while the second carries a separate indicator or interlock path. Because the normally closed contact is closed at rest, the de-energized state of each path is defined in the drawing from the start.
A: No. The 150 mW option is the lowest of three coil power groups, alongside about 0.20 W and 0.36 W. Coil voltages are 3, 5, 6, 9, 12, and 24 VDC, and availability depends on the full ordering code. The 0.36 W group has a data inconsistency to confirm, and the ordering code for the 0.15 W version is not spelled out in the published data, so request it with the exact voltage you need.
Relay Switch Circuit and Types of Relay Switching Circuits
Electromagnetic Compatibility (EMC) Directive - Internal Market, Industry, Entrepreneurship and SMEs